Use a strain relief clamp on cable.
Use the correct mains cable of type H05BB-F Tmax 90°C (or higher) for a single phase or
two phase connection.
Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; or
higher). Speak your local Service Centre.
The appliance must have the electrical installation which lets you disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm.
You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips and contactors.
To attach the seal to the rabbet
Clean the rabbet in the work surface.
Bond the seal stripe supplied on the upper surface of the rabbet along the edges of the
cut out section.
Cut the seal stripe into four pieces in relation to the length of the edges of the rabbet.
For the four corners of the rabbet the ends of the seal stripes must be cut into mitres. Do
not bond the ends over one another.
Bond the seal stripe flush into the corner of the rabbet. Make sure that no silicon com-
pound can get below the glass ceramic when grouting.
Do not extend the tapes.
Assembly
min. 500 mm
min.
50 mm
min.
50 mm
584
+1
mm
514
+1
mm
490
+1
mm
min. 600mm
560
+1
mm
R10mm
R5mm
12mm
7mm
min.
25 mm
min.
20 mm
min.
28 mm
20 Installation instructions