the appliance makes an unusual noise during draining due to objects such as safety pins,
coins etc. blocking the pump;
a problem with water draining is detected (see chapter “What to do if...” for more de-
tails).
WARNING!
Before opening the pump door, switch the appliance off remove the mains plug from the
socket.
Proceed as follows:
1. Unplug the appliance.
2. If necessary wait until the water has cooled down.
3. Open the pump door.
4. Pull flap forward to remove.
5. Place a container close to the pump to
collect any spillage.
6. Pull out the emergency emptying hose,
place it in the container and remove its
cap.
7. When no more water comes out, un-
screw the pump cover by turning it an-
ti-clockwise and remove the filter. Use
pliers, if necessary. Always keep a rag
nearby to dry up any water spillages
when removing the cover.
Clean the filter under a tap, to remove
any traces of fluff.